UPS Systems Built for Server Rooms That Can't Go Down
Right-sized systems
Rack-mount for cabinet environments, tower for open server rooms, sized to your actual equipment load
Lithium-ion battery options
Smaller footprint, longer lifespan, and faster recharge than traditional VRLA batteries
Authorized APC by Schneider Electric distributor
Genuine hardware, full manufacturer warranty
In-house deployment team
Installation, cable management, and PDU setup handled end to end
Lithium-Ion vs. Traditional UPS Batteries
Traditional VRLA Batteries
Upfront cost: Lower initial equipment investment
Rack footprint: Bulkier and heavier inside the cabinet
Lifespan: Typically requires replacement every 3–5 years
Recharge cycle: Standard recharge recovery time
Traditional batteries can still make sense for lower-budget, less space-sensitive setups.
Lithium-Ion UPS Batteries
Upfront cost: Higher initial investment
Rack footprint: Compact footprint, saving critical rack U-space
Lifespan: Lasts 8–10 years (2–3x longer lifespan)
Recharge cycle: Recharges significantly faster after an outage
Often the better choice for a server room where rack space and long-term maintenance visits both matter.
Traditional VRLA (lead-acid) batteries are lower upfront cost but bulkier, heavier, and typically need replacement every 3–5 years. Lithium-ion UPS batteries cost more initially but take up less rack space, last significantly longer, and recharge faster after an outage — often the better choice for a server room where rack space and long-term maintenance visits both matter.
Server Room UPS — Common Questions
Add up the VA/watt rating of everything you're protecting — servers, switches, storage — and size the UPS with headroom for future growth, not just today's load. We do this calculation based on your actual equipment list rather than a generic sizing chart.
Rack-mount UPS units fit directly into a server rack alongside your other equipment and are the standard choice when you already have a rack. Tower units make more sense for smaller, open server rooms without a full rack setup.
It depends on your timeline and rack space. Lithium-ion batteries cost more upfront but last longer and take up less space, which often makes them the better long-term value in a space-constrained server room — traditional batteries can still make sense for lower-budget, less space-sensitive setups.
A basic PDU distributes power without remote control or monitoring. A switched PDU lets you remotely power-cycle individual outlets — useful for a server room you don't want to physically visit for every reboot. A metered PDU adds outlet-level power monitoring on top of that.
Enough to either ride out short outages or safely shut equipment down gracefully — most server room deployments target 5–15 minutes unless there's a generator handoff involved, in which case runtime is sized to bridge that gap specifically.
Not fundamentally — the difference is sizing and configuration, not the underlying technology. A server room needs battery backup for servers specifically, which usually means higher capacity, rack-mount form factors, and remote monitoring that a basic consumer UPS doesn't offer.
Yes, within limits — some rack-mount systems support additional external battery packs for extended runtime, and PDUs can be added or swapped as your rack grows. For significant load growth beyond what your current unit supports, a modular data center-class system (see our Data Center & Enterprise UPS solutions) is usually the better long-term fit.
Featured Products
View AllSetting up or upgrading a server room?
Tell us what's in your rack and we'll recommend the right UPS, battery type, and PDU setup.
What Happens After You Submit
Requirement Review
A member of our team reviews what's in your rack
Consultation Follow-up
We'll follow up to talk through sizing, battery type, and PDU needs
Custom Sizing Recommendations
You'll get a recommendation matched to your actual setup, not a generic package